Innovations
in Communications™ Since 1955
LEE DAN® COMMUNICATIONS, INC. 155 Adams Avenue, Hauppauge, New York, 11788-3699 USA Phone: 800-231-1414 or 631-231-1414 Fax: 631-231-1498 E-Mail: info@leedan.com Loading
|
|
5540MV Series |
Adaptatone®
Millennium Central Tone Generator Voice Messaging & System Signaling, Four Outputs, RS485 Edwards is a registered trademark of UTC Fire & Security |
The Edwards 5540MV Adatpatone Millennium Central Tone Generator with Voice messaging has been designed for applications where simultaneous signaling of a high decibel, heavy duty signal and prerecorded voice messaging is required. The tone generator assures a synchronous signaling sound from all remote speakers. The Millennium Central Tone Generator produces the 27 standard Adaptatone sounds and can store 20 seconds of field recorded voice messages. Four signals may be activated from field-wired, normally open contacts, or a 24VDC external voltage source such as an output of a PLC. Normally open contacts can be obtained from the Cat. No. 5538-4 or Cat. No. 5538-4R Adaptatone Signal Actuator. Messages and tones may be selected by setting miniature dip switches within the unit. The programmed tones operate on a pyramid-type priority system. The 5540MV-485Y6 is designed to be connected to RS485 networks, allowing full serial signaling communication control. Adaptatone Signaling Systems are designed for industrial applications calling for high decibel output and microprocessor reliability combined with simultaneous signal delivery over all speakers included in the system. Typical applications include: emergency warning systems, plant evacuation alarms, security intrusion sirens, process monitoring, shift start-and-dismissal horns & paging signals. RS485 units are MEDI compatible. |
|
Features |
27 tone
capability- No additional tone modules needed PLC compatible 20 sec. of field recorded Voice Suitable for Division 2 Locations Centralized programmable tone selection System-wide priority tone selection RS485 model available |
Agency Approvals |
NEMA Type 3R IP 44 |
UL 464 and 1604 Listed UL & cUL Listed for indoor and outdoor applications in Class I, Division 2, Groups A, B, C, & D; Class II Division 2, Groups F & G; and Class III Hazardous Locations cUL C22.2 No. 205 CE Marked- Cenelec LV & EMC Directives (24Y6 AC model only) |
Specifications |
24V DC battery backup terminals Built in Presignal tone option on first message location |
Short Circuit protected |
| Brochure | Doc | Spec Sheet | User Guide | Manual | Wiring | |
This page was last updated August 19, 2014
|