UL AUDIBLE-VISUAL ROOM STATION


 

 

The SF101C (SF-101C) Room Station incorporates push-button operation of call and cancel functions. A call is registered at the annunciator panel and on a corridor light or corridor zone light (if installed) when the call switch with integral call-placed LED is pushed. The call-placed LED will also illuminate. Calls are canceled by simply depressing the cancel button. The call-placed LED will also be extinguished. All station components shall be mounted on a rugged UL® 94V-0 plastic faceplate.

FEATURES

UL® 1069 Listed

Simple, push button calling

Call-placed indicator and cancel button

Call activates lamp on annunciator panel and corridor light

Flame retardant (UL® 94V-0) plastic faceplate

Corridor zone light capability

SPECIFICATIONS

Height: 4.50" (114 mm) Width: 2.75" (69 mm) Depth: 1.75" (44 mm) Projects: 0.4375" (11 mm) from mounting surface

Construction: Attractive, flame retardant (UL® 94V-0) plastic faceplate. Switches and electronic components are circuit board mounted.

Connections: Plug-in connectors.

Housing: Single gang ring (IH357) with square box (IH358).

REQUIRED COMPONENTS

Tek-CARE® NC110 Nurse Call System

Click for Spec Sheet

Architects' & Engineers' Specifications:

 

The room station shall be TekTone® SF101C (SF-101C) or approved equal as supplied by LEE DAN®, and shall include an integral call-placed LED, a call button and a cancel button. A call shall be registered at the annunciator panel, a corridor light or corridor zone light (if installed), and the station’s call-placed LED. All electronic components needed for these features and functions shall be mounted on a printed circuit board and all station components shall be mounted on a rugged UL® 94V-0 plastic faceplate. The station shall be installed in a single gang ring with square box. Plug-in connectors shall be provided for connections.

The SF101C shall be UL® 1069 Listed.

 

 

 

 